SINTHA MAHARANI LUHUR, NIM 112019173 (2024) PERENCANAAN STRUKTUR ATAS BANGUNAN GEDUNG 4 LANTAI. Skripsi thesis, Universitas Muhammadiyah Palembang.
|
Text
112019173_BAB I_DAFTAR PUSTAKA.pdf - Published Version Download (945kB) | Preview |
|
Text
112019173_BAB II.pdf - Published Version Restricted to Repository staff only Download (461kB) |
||
Text
112019173_BAB III.pdf - Published Version Restricted to Repository staff only Download (1MB) |
||
Text
112019173_BAB IV.pdf - Published Version Restricted to Repository staff only Download (719kB) |
||
Text
112019173_BAB V.pdf - Published Version Restricted to Repository staff only Download (45kB) |
||
Text
112019173_DAFTAR PUSTAKA.pdf - Published Version Restricted to Repository staff only Download (45kB) |
||
Text
112019173_LAMPIRAN.pdf - Published Version Restricted to Repository staff only Download (861kB) |
||
Text
112019173_Cover_sampai_Lampiran.pdf - Published Version Restricted to Repository staff only Download (3MB) |
Abstract
ABSTRACT Every building, the components of all its structures must have the strength to withstand the loads they bear. Beams and columns are very important structural components in building construction, for this reason these two structural components must be calculated and analyzed based on the appropriate combination of factored loads and forces. The purpose of this research is to plan beam and column structures using the SAP 2000 program and empirical calculations using excel, so as to produce a structure that is safe, efficient and economical. planning the beam and column structure of the building by analyzing the structural loading due to dead load, live load, and wind load. planning safe and efficient cross-sectional dimensions of beams and columns. planning safe or unsafe variations of beams and columns. Based on the results of the program output and analysis carried out by the panel of researchers, the results of the analysis can be concluded that variation 1 is a safe and efficient variation because the column and beam sizes are the smallest, and has a structure to support the planned loads. Marked by the absence of overstress warnings on the cross section. And variation 4 cannot be used because the dimensions of the columns and beams in the design do not meet the requirements, so an overstress warning is indicated. In variation 1 with column dimensions (25 x25) and beam dimensions (30 x 20). For beam size (30 x 20), 6D12 reinforcement, 25 Mpa concrete quality and Ø8-120 reinforcement. For column size (25 x 25), 6D16 reinforcement, concrete quality 25 Mpa and reinforcement Ø8- 120mm. With the SAP 2000 program, it makes it easier to calculate structures. Keywords: Hospital Buildings, Variation of beams and columns
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | Pembimbing : 1. Muhammad Arfan,S.T., M.T Pembimbing : 2. Mira Setiawati,S.T., M.T |
Uncontrolled Keywords: | Keywords: Hospital Buildings, Variation of beams and columns |
Subjects: | Teknik Sipil > Teknik Struktural |
Divisions: | Fakultas Teknik > Teknik Sipil (S1) |