CHOIRUNNISA FEBRIANTI, NIM. 112018030 (2022) RE DESIGN STRUKTUR KOLOM DAN BALOK PADA GEDUNG BARU FAKULTAS KEDOKTERAN UNIVERSITAS INDO GLOBAL MANDIRI (UIGM) PALEMBANG. Skripsi thesis, Universitas Muhammadiyah Palembang.
|
Text
112018030_BAB I_DAFTAR PUSTAKA.pdf Download (1MB) | Preview |
|
Text
112018030_BAB II.pdf Restricted to Repository staff only Download (654kB) |
||
Text
112018030_BAB III.pdf Restricted to Repository staff only Download (448kB) |
||
Text
112018030_BAB IV.pdf Restricted to Repository staff only Download (1MB) |
||
Text
112018030_BAB V.pdf Restricted to Repository staff only Download (10kB) |
||
Text
112018030_Cover_sampai_Lampiran.pdf Restricted to Repository staff only Download (3MB) |
||
Text
112018030_DAFTAR PUSTAKA.pdf Restricted to Repository staff only Download (208kB) |
||
Text
112018030_LAMPIRAN.pdf Restricted to Repository staff only Download (364kB) |
Abstract
ABSTRACT Building planning must be carried out efficiently so that construction costs can be as much as possible, but still safe against the existing load. The crosssectional size, material composition, and load factor are the main requirements of building structural planning. Beams and columns are structures formed by placing horizontal rigid elements on top of vertical rigid elements. The beam carries the load transversely from its length and transfers the load to the vertical column that supports it. The column is loaded axially by the beam and transfers the load to the soil or foundation. The results of the planning of the new building of the UIGM medical faculty there are several variations of buildings that can reduce the existing load, namely variation 1 of 1793,549 kN can reduce the existing building by 5.6 % and variation 2 of 1747.75 kN can reduce the existing building by 8% and variation 3 has a structural failure. From these results it can be concluded that the efficient variation of beams and columns is variation 2 where the dimensions of Column K1(45x45) cm, K2(35x35) cm, Beam B1(30x45) cm, B2(25x45) cm, B3(15x45) cm, B4 (25x25), Column K1(45x45) cm, K2(35x35) cm Keywords: Building planning, Beams and Columns, Planning Results
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | PEMBIMBING : 1. Muhammad Arfan,ST.MT 2. Ir Lukman Muizzi, MT |
Uncontrolled Keywords: | Building planning, Beams and Columns, Planning Results |
Subjects: | Teknik Sipil > Penyelesaian detail dalam Bangunan |
Divisions: | Fakultas Teknik > Teknik Sipil (S1) |
Depositing User: | Mahasiswa Fakultas Teknik |
Date Deposited: | 15 Nov 2022 07:13 |
Last Modified: | 15 Nov 2022 07:13 |
URI: | http://repository.um-palembang.ac.id/id/eprint/23410 |
Actions (login required)
View Item |