ILHAM, NIM. 132015061 (2019) ANALISIS INDEKS KEANDALAN SISTEM DISTRIBUSI PENYULANG KIKIM DI GARDU INDUK SUNGAI JUARO MENGGUNAKAN METODE SECTION TECHNIQUE. Skripsi thesis, Universitas Muhammadiyah Palembang.
|
Text
132015061_BAB I_DAFTAR PUSTAKA.pdf Download (611kB) | Preview |
|
Text
132015061_BAB II_SAMPAI_BAB TERAKHIR.pdf Restricted to Repository staff only Download (1MB) |
Abstract
Most of the blackout in an electric power system is due to problems that occur in the distribution system, so it is necessary to measure the reliability index. This analysis aims to evaluate the reliability of the Kikim redistribution system in the Juaro River parent garrison using the Section Technique method. THE result of the calculation obtained by SAIDI value 8.67 hours/year, SAIFI amounted to 2.954 times/year and CAIDI amounting to 2.93 hours/year. Based on the SPLN No. 59:1985, THE value of SAIDI is 21 hours/year, SAIFI amounted to 3.2 times/year and CAIDI of 6.56 hours/year. Kikim's refills meet PLN standards for SAIFI, SAIDI, and CAIDI grades. Keywords : Reliability, Section Technique, SAIFI, SAIDI, CAIDI
Item Type: | Thesis (Skripsi) |
---|---|
Additional Information: | Pembimbing, 1. Wiwin. A. Oktaviani, S.T., M.Sc 2. Taufik Barlian, S.T., M. Eng |
Uncontrolled Keywords: | Reliability, Section Technique, SAIFI, SAIDI, CAIDI |
Subjects: | Elektro > Pengujian dan Pengukuran Listrik |
Divisions: | Fakultas Teknik > Teknik Elektro (S1) |
Depositing User: | Mahasiswa Fakultas Teknik |
Date Deposited: | 12 Oct 2019 06:40 |
Last Modified: | 12 Oct 2019 06:40 |
URI: | http://repository.um-palembang.ac.id/id/eprint/5731 |