PENGARUH PEMBEBANAN LEBIH PADA SUHU OPERASI MOTOR INDUKSI 3 FASA SEBAGAI PENGGERAK POMPA SENTRIFUGAL DI PT INTEGRATED TERMINAL PALEMBANG

Muhammad Rio Ferdinan Powa, 132022035 (2026) PENGARUH PEMBEBANAN LEBIH PADA SUHU OPERASI MOTOR INDUKSI 3 FASA SEBAGAI PENGGERAK POMPA SENTRIFUGAL DI PT INTEGRATED TERMINAL PALEMBANG. Skripsi thesis, UNIVERSITAS MUHAMMADIYAH PALEMBANG.

[img] Text
132022035_BAB 1_DAFTAR PUSTAKA.pdf - Published Version

Download (717kB)
[img] Text
132022035_BAB 2_TINJAUAN PUSTAKA.pdf - Published Version
Restricted to Repository staff only

Download (745kB)
[img] Text
132022035_BAB 3_METODE PENELITIAN.pdf - Published Version
Restricted to Repository staff only

Download (310kB)
[img] Text
132022035_BAB 4_HASIL DAN PEMBAHASAN.pdf - Published Version
Restricted to Repository staff only

Download (654kB)
[img] Text
132022035_BAB 5_KESIMPULAN DAN SARAN.pdf - Published Version
Restricted to Repository staff only

Download (192kB)
[img] Text
132022035_DAFTAR PUSTAKA.pdf - Published Version
Restricted to Repository staff only

Download (203kB)
[img] Text
132022035_LAMPIRAN.pdf - Published Version
Restricted to Repository staff only

Download (346kB)
[img] Text
132022035_M RIO FERDINAN POWA_SKRIPSI.pdf - Published Version
Restricted to Repository staff only

Download (1MB)

Abstract

ABSTRAK Motor induksi tiga fasa merupakan salah satu mesin listrik yang banyak digunakan dalam sistem produksi industri sebagai penggerak berbagai peralatan. Dalam pengoperasiannya, perubahan beban kerja dapat menyebabkan perubahan arus dan rugi-rugi daya yang selanjutnya memengaruhi suhu operasi motor. Penelitian ini bertujuan untuk menganalisis hubungan antara pembebanan dan suhu operasi motor induksi tiga fasa serta menentukan kondisi operasi motor pada sistem produksi di PT Integrated Terminal Palembang. Metode penelitian yang digunakan adalah metode kuantitatif dengan melakukan pengumpulan data pembebanan dan suhu operasi motor selama proses produksi. Data yang diperoleh kemudian dianalisis menggunakan analisis korelasi Pearson dan regresi linear sederhana. Hasil penelitian menunjukkan bahwa pembebanan motor berada pada rentang 55% hingga 97%, sedangkan suhu operasi motor berada pada rentang 29,8°C hingga 43,2°C. Hasil analisis korelasi Pearson memperoleh nilai koefisien korelasi sebesar 0,995 yang menunjukkan hubungan sangat kuat dan positif antara pembebanan dengan suhu operasi motor. Analisis regresi linear menghasilkan persamaan Y = 10,026 + 0,343X, yang menunjukkan bahwa setiap peningkatan pembebanan sebesar 1% diperkirakan meningkatkan suhu operasi sebesar 0,343°C. Nilai koefisien determinasi sebesar 0,991 menunjukkan bahwa 99,1% variasi suhu operasi dapat dijelaskan oleh perubahan pembebanan motor, sedangkan 0,9% dipengaruhi oleh faktor lain. Berdasarkan hasil tersebut, peningkatan pembebanan motor memiliki hubungan yang sangat kuat dengan peningkatan suhu operasi, sehingga pemantauan pembebanan dan suhu diperlukan untuk menjaga kondisi operasi motor tetap optimal. ABSTRACT Three-phase induction motors are widely used in industrial production systems as prime movers for various equipment. During operation, changes in motor load can cause changes in current and power losses, which subsequently affect the operating temperature of the motor. This study aims to analyze the relationship between motor loading and the operating temperature of a three-phase induction motor and to determine the optimal operating conditions in the production system at PT Integrated Terminal Palembang. The research used a quantitative method by collecting motor loading and operating temperature data during the production process. The collected data were analyzed using Pearson correlation and simple linear regression analysis. The results showed that the motor loading ranged from 55% to 97%, while the operating temperature ranged from 29.8°C to 43.2°C. Pearson correlation analysis resulted in a correlation coefficient of 0.995, indicating a very strong and positive relationship between motor loading and operating temperature. Simple linear regression produced the equation Y = 10.026 + 0.343X, indicating that every 1% increase in motor loading is estimated to increase the operating temperature by approximately 0.343°C. The coefficient of determination 0.991 indicates that 99.1% of the variation in operating temperature can be explained by changes in motor loading, while the remaining 0.9% is influenced by other factors. Based on these results, increased motor loading has a very strong relationship with increased operating temperature. Therefore, monitoring motor loading and temperature is necessary to maintain optimal motor operating conditions.

Item Type: Thesis (Skripsi)
Additional Information: PEMBIMBING 1 : Asri Indah Lestari, S.T., M.T, PEMBIMBING 2 : Taufik Barlian, S.T., M.Eng,
Uncontrolled Keywords: Kata kunci: Motor induksi tiga fasa, pembebanan motor, suhu operasi, korelasi Pearson, regresi linear. Keywords: Three-phase induction motor, motor loading, operating temperature, Pearson correlation, linear regression.
Subjects: Elektro > Teknik Listrik
Divisions: Fakultas Teknik > Teknik Elektro (S1)
Depositing User: Mahasiswa Fakultas Teknik
Date Deposited: 23 Sep 2026 02:50
Last Modified: 23 Sep 2026 02:50
URI: http://repository.um-palembang.ac.id/id/eprint/37557

Actions (login required)

View Item View Item

is powered by EPrints 3 which is developed by the School of Electronics and Computer Science at the University of Southampton. More information and software credits.